2.7MM Extra Articular Distal Radius LCP - Volar Left & Right 2.7MM Extra Articular Distal Radius LCP - Volar Left & Right

2.7MM Extra Articular Distal Radius LCP - Volar Left & Right

Variable angle locking, anatomically pre-contoured for extra-articular distal radius fractures.

volar extra-articular distal radius plate. the anatomically pre-contoured plates featuring variable angle locking are indicated for fixation of intra- and extra-articular fractures and osteotomies of the distal radius.

2.7MM Extra Articular Distal Radius LCP - Volar Left & Right 2.7MM Extra Articular Distal Radius LCP - Volar Left & Right

volar extra-articular distal radius plate. the anatomically pre-contoured plates featuring variable angle locking are indicated for fixation of intra- and extra-articular fractures and osteotomies of the distal radius. 2.4/2.7MM Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left is used or fixation of complex intra and extra-articular fractures and osteotomies of the distal radius and other small bones.

  • Extra-Articular Distal Radius Fractures: AO Type 23-A fractures (A2 and A3 subtypes) Simple transverse or oblique fractures proximal to the radiocarpal joint
  • Osteoporotic or Fragility Fractures: Distal radius fractures in elderly patients with poor bone quality requiring angular-stable fixation
  • Metaphyseal Instability: Fractures with dorsal comminution or volar cortex disruption requiring volar buttressing
  • Fractures Requiring Early Mobilization:Stable fixation to allow functional recovery and rehabilitation in early stages
  • Corrective Osteotomies: Realignment of malunited distal radius fractures not involving the joint surface
  • Nonunions: Treatment of nonunited distal radius fractures without intra-articular involvement
  • 2.4/2.7MM Locking Plate Extra-Articular Volar Distal Radius 5 Hole Head Type-III, Right/Left is precontoured with a complex bend designed to fit the volar surface of the distal radius. Juxta-articular plates may be used for more complex fractures. Placement is as distal as possible on the radius. The locking holes in the head of the plate are angled 5° proximal to the articular surface, to allow a more distal plate placement.
  • Straight plates are contoured to fit the radial column and have a notched tip that allows them to fit on the radial styloid, adjacent to a temporary K-wire fixation.
  • Locking Compression Plates (LCP) have Combi holes which allow locking screw fixation in the threaded section or compression in the non-threaded section of the hole.
  • Locking screws offer a fixed-angle construct to support the articular surface, reduce the need for bone graft, and obtain fixation in osteoporotic bone.
  • Undercuts on the bottom of the plate head facilitate contouring of the plate to match the anatomy of the distal radius and minimize the potential for soft tissue irritation.
  • Rounded edges minimize potential for tendon adhesion.
  • Smaller plates and screws address fracture fragments individually, with less overall implant bulk.
  • Plate available with 5 head holes and 3 and 5 shaft holes.
  • Plates available for Left and Right.
  • Plates available in Titanium.

Detailed surgical technique guides, sterilization instructions and compatibility charts are available in the product catalogue or on request from our clinical support team.

Holes Left SS Left TI Right SS Right TI
3 HOLES 1040SS03 1040TI03 1041SS03 1041TI03
4 HOLES 1040SS04 1040TI04 1041SS04 1041TI04
5 HOLES 1040SS05 1040TI05 1041SS05 1041TI05
6 HOLES 1040SS06 1040TI06 1041SS06 1041TI06