Ø3.5MM Peri Proximal Tibia Raft LCP Ø3.5MM Peri Proximal Tibia Raft LCP

Ø3.5MM Peri Proximal Tibia Raft LCP

A raft of subchondral screws, to buttress and maintain reduction of the articular surface.

The 3.5MM LCP Proximal Tibia Plates have a limited-contact profile. The head and neck portions of the plates accept 3.5MM locking screws with StarDriveTM Recess. The screw hole pattern allows a raft of subchondral locking screws to buttress and maintain reduction of the articular surface. This provides resistance to local depression loads in addition to the stability of the fixed-angle construct created by locking the screws into the plate.

Ø3.5MM Peri Proximal Tibia Raft LCP Ø3.5MM Peri Proximal Tibia Raft LCP

The 3.5MM LCP Proximal Tibia Plates have a limited-contact profile. The head and neck portions of the plates accept 3.5MM locking screws with StarDriveTM Recess. The screw hole pattern allows a raft of subchondral locking screws to buttress and maintain reduction of the articular surface. This provides resistance to local depression loads in addition to the stability of the fixed-angle construct created by locking the screws into the plate.

The Locking Compression Plate (LCP) has Combi holes in the plate shaft which combine a dynamic compression unit (DCU) hole with a locking screw hole. The Combi hole provides flexibility of axial compression and locking capability throughout the length of the plate shaft.

  • The 3.5MM LCP Proximal Tibia Plate and 3.5MM LCP Proximal Tibia Plate—Low Bend are indicated for fractures of the proximal tibia, including: simple, coMMinuted,lateral wedge, depression, medial wedge, bicondylar combination of lateral wedge and depression, periprosthetic, and fractures with associated shaft fractures. The plates can also be used for treatment of nonunions, malunions, and osteopenic bone.
  • Available in left and right plates. Plates available in implant-quality 316L stainless steel or coMMercially pure (CP) titanium.
  • The three locking holes distal to the plate head accept 3.5MM locking screws with StarDrive Recess to secure plate position. The hole angles allow the locking screws to converge with three of the four locking screws in the plate head to support medial.
  • Anatomically contoured to match the lateral proximal tibia
  • Four convergent threaded screw holes accept 3.5MM locking screws with StarDrive Recess
  • Three 2.0MM holes for preliminary fixation with K-wires, or meniscal repair with sutures
  • Combi holes, distal to the three angled locking holes, combine a DCU hole with a threaded locking hole. The Combi holes accept 3.5MM locking screws with StarDrive Recess in the threaded portion of the hole and 3.5MM cortex screws or 3.5MM shaft screws in the DCU portion of the hole.

Detailed surgical technique guides, sterilization instructions and compatibility charts are available in the product catalogue or on request from our clinical support team.

Holes Left SS Left TI Right SS Right TI
4 HOLES 1080SS04 1080TI04 1081SS04 1081TI04
6 HOLES 1080SS06 1080TI06 1081SS06 1081TI06
8 HOLES 1080SS08 1080TI08 1081SS08 1081TI08
10 HOLES 1080SS10 1080TI10 1081SS10 1081TI10
12 HOLES 1080SS12 1080TI12 1081SS12 1081TI12
14 HOLES 1080SS14 1080TI14 1081SS14 1081TI14