Ø3.5MM T-medial Proximal Tibia LCP Ø3.5MM T-medial Proximal Tibia LCP

Ø3.5MM T-medial Proximal Tibia LCP

A raft of subchondral screws, providing fixed-angle support to the tibial plateau.

The 3.5MM LCP Medial Proximal Tibia Plate is available in stainless steel or titanium and has a limited-contact shaft profile. The head and neck portions of the plate accept 3.5MM locking screws and 3.5MM conical screws. The screw hole pattern allows a raft of subchondral locking screws to buttress and maintain reduction of the articular surface. This provides fixed-angle support to the tibial plateau.

Ø3.5MM T-medial Proximal Tibia LCP Ø3.5MM T-medial Proximal Tibia LCP

The 3.5MM LCP Medial Proximal Tibia Plate is available in stainless steel or titanium and has a limited-contact shaft profile. The head and neck portions of the plate accept 3.5MM locking screws and 3.5MM conical screws. The screw hole pattern allows a raft of subchondral locking screws to buttress and maintain reduction of the articular surface. This provides fixed-angle support to the tibial plateau.

The locking compression plate (LCP) has Combi holes in the plate shaft that combine a dynamic compression unit (DCU) hole with a locking screw hole. The Combi hole provides the flexibility of axial compression and locking capabilit throughout the length of the plate shaft.

The 3.5MM LCP Posteromedial Proximal Tibia Plate is indicated for internal fixation of posteromedial proximal tibia fractures including buttressing of fractures of the proximal, distal, and metaphyseal areas of the tibia.

  • Anatomically contoured to approximate the anteromedial proximal tibia.
  • Three convergent threaded screw holes accept 3.5MM locking screws or 3.5MM conical screws.
  • Two 2.0MM holes for preliminary fixation with K-wires, or meniscal repair with sutures.
  • The two angled locking holes distal to the plate head accept 3.5MM locking screws or 3.5MM conical screws, to secure the plate position. The hole angles allow the locking screws to converge with two of the three screws in the plate head.
  • Combi holes, distal to the angled locking holes, combine a DCU hole with a threaded locking hole. The Combi holes accept 3.5MM locking screws or 3.5MM conical screws in the threaded portion of the hole and 3.5MM cortex screws or 3.5MM shaft screws in the DCU portion of the hole.

Detailed surgical technique guides, sterilization instructions and compatibility charts are available in the product catalogue or on request from our clinical support team.

Holes Left SS Left TI Right SS Right TI
4 HOLES 1082SS04 1082TI04 1083SS04 1083TI04
6 HOLES 1082SS06 1082TI06 1083SS06 1083TI06
8 HOLES 1082SS08 1082TI08 1083SS08 1083TI08
10 HOLES 1082SS10 1082TI10 1083SS10 1083TI10
12 HOLES 1082SS12 1082TI12 1083SS12 1083TI12